lj_plc/Actions/ChemicalWeighing/Mesnac.Action.ChemicalWeighing/BasePlcHelper.cs

876 lines
36 KiB
C#

This file contains ambiguous Unicode characters!

This file contains ambiguous Unicode characters that may be confused with others in your current locale. If your use case is intentional and legitimate, you can safely ignore this warning. Use the Escape button to highlight these characters.

using System;
using System.Collections.Generic;
using System.Linq;
using System.Text;
using System.Threading.Tasks;
using System.Data;
using System.Reflection;
using ICSharpCode.Core;
using Mesnac.Basic;
using Mesnac.Equips;
using Mesnac.Codd.Session;
using Mesnac.Action.ChemicalWeighing.Entity;
namespace Mesnac.Action.ChemicalWeighing
{
/// <summary>
/// Plc操作辅助类
/// </summary>
public class BasePlcHelper
{
#region 单例模式
private static BasePlcHelper _this = null;
public static BasePlcHelper Instance
{
get
{
if (null == _this)
_this = new BasePlcHelper();
return _this;
}
}
private BasePlcHelper()
{
foreach (PropertyInfo pi in this.GetType().GetProperties())
{
if (pi.PropertyType == typeof(DataKeyValue))
{
DataKeyValue data = new DataKeyValue(pi.Name);
pi.SetValue(this, data, null);
}
}
}
#endregion
#region 方法定义
#region GetDataKeyValue
public DataKeyValue GetDataKeyValue(string key)
{
foreach (PropertyInfo pi in this.GetType().GetProperties())
{
if (pi.PropertyType == typeof(DataKeyValue))
{
DataKeyValue data = (DataKeyValue)pi.GetValue(this, null);
if (data.FieldKey.ToLower() == key.ToLower())
{
return data;
}
}
}
return null;
}
#endregion
#region 从PLC中读取原始数据的方法
/// <summary>
/// 从PLC中读取原始数据
/// </summary>
/// <param name="dataName">要读取的设备变量名称</param>
/// <param name="dataValue">从PLC读取的值</param>
/// <returns>成功返回true失败返回false</returns>
public bool PlcRead(string dataName, out int[] dataValue)
{
return Mesnac.Equips.Factory.Instance.Read(dataName, out dataValue);
}
/// <summary>
/// 根据设备名称读取指定数据块,指定起始字,指定长度的数据
/// </summary>
/// <param name="equipName">设备名称</param>
/// <param name="block">数据块</param>
/// <param name="start">起始字</param>
/// <param name="len">长度</param>
/// <param name="dataValue">输出数据</param>
/// <returns>成功返回true失败返回false</returns>
public bool PlcRead(string equipName, string block, int start, int len, out Int16[] dataValue)
{
return Mesnac.Equips.Factory.Instance.Read(equipName, block, start, len, out dataValue);
}
/// <summary>
/// 从PLC中读取原始数据
/// </summary>
/// <param name="dataKey"></param>
/// <param name="dataValue"></param>
/// <returns></returns>
public bool PlcRead(DataKeyValue dataKey, out int[] dataValue)
{
return PlcRead(dataKey.EquipKey, out dataValue);
}
/// <summary>
/// 按设备变量别名从PLC读取数据
/// </summary>
/// <param name="runName">PLC设备变量别名</param>
/// <param name="dataValue">读取值</param>
/// <returns>读取成功返回true失败返回false</returns>
public bool PlcReadByRunName(string runName, out int[] dataValue)
{
return Mesnac.Equips.Factory.Instance.ReadByRunName(runName, out dataValue);
}
public object PlcLastValueRead(string dataName)
{
return Mesnac.Equips.Factory.Instance.ReadLastValue(dataName);
}
/// <summary>
/// 读取设备数据
/// </summary>
/// <param name="dataName">设备变量名称</param>
/// <param name="dataValue">读取的设备值</param>
/// <returns>读取成功返回true失败返回false</returns>
public bool PlcLastValueRead(string dataName, out int[] dataValue)
{
return Mesnac.Equips.Factory.Instance.ReadLastValue(dataName, out dataValue);
}
#endregion
#region 向PLC变量中写入值并不真正下传至PLC
/// <summary>
/// 向PLC变量中写入值并不真正下传至PLC
/// </summary>
/// <param name="equipKey"></param>
/// <param name="runName"></param>
/// <param name="shifting"></param>
/// <param name="dataValue"></param>
/// <returns></returns>
public bool PlcVarWrite(string equipKey, string runName, int shifting, object dataValue)
{
StringBuilder log = new StringBuilder();
try
{
//log.Append("equipKey=[").Append(equipKey).Append("]runName=[").Append(runName);
foreach (Mesnac.Equips.BaseEquip equip in Factory.Instance.AllEquips.Values)
{
foreach (Mesnac.Equips.BaseInfo.Group group in equip.Group.Values)
{
if (group.Access == System.IO.FileAccess.Write ||
group.Access == System.IO.FileAccess.ReadWrite)
{
foreach (Mesnac.Equips.BaseInfo.Data data in group.Data.Values)
{
if (data.KeyName == equipKey || (!String.IsNullOrEmpty(data.RunName) && data.RunName == runName))
{
try
{
data.Value = dataValue;
return true;
}
catch (Exception ex)
{
ICSharpCode.Core.LoggingService.Error(ex.Message);
return false;
}
}
}
}
}
}
//log.Append("]No Find");
return false;
}
catch (Exception ex)
{
ICSharpCode.Core.LoggingService.Error("写入PLC变量值失败" + ex.Message, ex);
return false;
}
finally
{
//if (log.Length > "equipKey=[]runName=[]No Find".Length)
//{
// action.LogDebug(log.AppendLine("...").ToString());
//}
}
}
/// <summary>
/// 向PLC变量中写入值并不真正下传至PLC
/// </summary>
/// <param name="equipKey"></param>
/// <param name="shifting"></param>
/// <param name="dataValue"></param>
/// <returns></returns>
public bool PlcVarWriteByDataKey(string equipKey, int shifting, object dataValue)
{
return PlcVarWrite(equipKey, string.Empty, shifting, dataValue);
}
/// <summary>
/// 向PLC变量中写入值并不真正下传至PLC
/// </summary>
/// <param name="dataKey"></param>
/// <param name="shifting"></param>
/// <param name="dataValue"></param>
/// <returns></returns>
public bool PlcVarWriteByDataKey(DataKeyValue dataKey, int shifting, object dataValue)
{
return PlcVarWriteByDataKey(dataKey.EquipKey, shifting, dataValue);
}
/// <summary>
/// 向PLC变量中写入值并不真正下传至PLC
/// </summary>
/// <param name="dataKey"></param>
/// <param name="dataValue"></param>
/// <returns></returns>
public bool PlcVarWriteByDataKey(DataKeyValue dataKey, object dataValue)
{
return PlcVarWriteByDataKey(dataKey, 0, dataValue);
}
#endregion
#region Plc写入方法真正写入PLC
/// <summary>
/// PlcWrite
/// </summary>
/// <param name="equipKey"></param>
/// <param name="runName"></param>
/// <param name="shifting"></param>
/// <param name="dataValue"></param>
/// <param name="isOutFlag"></param>
/// <returns></returns>
private bool PlcWrite(string equipKey, string runName, int shifting, object[] dataValue, params bool[] isOutFlag)
{
StringBuilder log = new StringBuilder();
try
{
log.Append("equipKey=[").Append(equipKey).Append("]runName=[").Append(runName);
foreach (Mesnac.Equips.BaseEquip equip in Factory.Instance.AllEquips.Values)
{
foreach (Mesnac.Equips.BaseInfo.Group group in equip.Group.Values)
{
if (group.Access == System.IO.FileAccess.Write ||
group.Access == System.IO.FileAccess.ReadWrite)
{
foreach (Mesnac.Equips.BaseInfo.Data data in group.Data.Values)
{
//if (data.KeyName == equipKey || data.RunName == runName)
//if (data.KeyName == equipKey)
if (data.KeyName == equipKey || (!String.IsNullOrEmpty(data.RunName) && data.RunName == runName))
{
int block = 0;
if (int.TryParse(group.Block.ToString(), out block))
{
log.Append("]shifting=[").Append((group.Start + data.Start + shifting).ToString());
log.Append("]dataLen=[").Append(dataValue.Length);
log.Append("]Find Result=");
foreach (object v in dataValue)
{
log.Append(v + ",");
}
#region 二进制位写入
if (data.Method.StartsWith("Default_Bit"))
{
string parameters = data.Method.Replace("Default_Bit(", String.Empty).Replace(")", String.Empty);
string[] ps = parameters.Split(new char[] { ',' });
int startIndex = 0;
int length = 1;
if (ps.Length == 1) //单参数判断
{
if (!int.TryParse(ps[0], out startIndex))
{
log.Append("[false](Convert The Bit method first parameter to int failure!)");
return false;
}
}
else if (ps.Length == 2) //多参数判断
{
if (!int.TryParse(ps[0], out startIndex))
{
log.Append("[false](Convert The Bit method first parameter to int failure!)");
return false;
}
if (!int.TryParse(ps[1], out length))
{
log.Append("[false](Convert The Bit method second parameter to int failure!)");
return false;
}
}
object originalValue = 0; //保存原始值
if (data.Len == 1) //如果len=1则为Int16类型
{
int[] buff = null;
if (PlcRead(data.KeyName, out buff))
{
originalValue = buff[0];
}
else
{
ICSharpCode.Core.LoggingService<BasePlcHelper>.Warn(String.Format("在进行二进制写入时读取设备变量[{0}]失败!", data.KeyName));
}
}
else if (data.Len == 2) //如果len=2则为Int32类型
{
int[] buff = null;
if (PlcRead(data.KeyName, out buff))
{
if (equip.Main.Brand == Mesnac.Basic.PlcBrand.Siemens)
{
originalValue = Mesnac.Basic.DataProcessor.ToSiemensInt32(buff);
}
else
{
originalValue = Mesnac.Basic.DataProcessor.ToInt32(buff);
}
}
else
{
ICSharpCode.Core.LoggingService<BasePlcHelper>.Warn(String.Format("在进行二进制写入时读取设备变量[{0}]失败!", data.KeyName));
}
}
object[] newValue = null;
if (data.Len == 1)
{
newValue = new object[] { Mesnac.Basic.DataProcessor.SetBitValue(originalValue, startIndex, length, dataValue[0]) };
}
else if (data.Len == 2)
{
object objNewValue = Mesnac.Basic.DataProcessor.SetBitValue32(originalValue, startIndex, length, dataValue[0]);
int intNewValue = Convert.ToInt32(objNewValue);
if (equip.Main.Brand == Mesnac.Basic.PlcBrand.Siemens)
{
newValue = Mesnac.Basic.DataProcessor.ToSiemensPLCDataArray(intNewValue);
}
else
{
newValue = Mesnac.Basic.DataProcessor.ToPLCDataArray(intNewValue);
}
}
if (equip.Write(block, group.Start + data.Start + shifting, newValue))
{
log.Append("[true]");
return true;
}
else
{
log.Append("[false]");
return false;
}
}
#endregion
if (equip.Write(block, group.Start + data.Start + shifting, dataValue))
{
log.Append("[true]");
return true;
}
else
{
log.Append("[false]");
return false;
}
}
}
}
}
}
}
log.Append("]No Find");
return false;
}
catch (Exception ex)
{
ICSharpCode.Core.LoggingService<BasePlcHelper>.Error("下传PLC失败" + ex.Message, ex);
return false;
}
finally
{
if (isOutFlag.Length == 0 || isOutFlag[0] == true)
{
if (log.Length > "equipKey=[]runName=[]No Find".Length)
{
ICSharpCode.Core.LoggingService<BasePlcHelper>.Debug(log.AppendLine("...").ToString());
}
}
}
}
public bool PlcWriteByRunName(string runName, int shifting, object[] dataValue)
{
return PlcWrite(string.Empty, runName, shifting, dataValue);
}
public bool PlcWriteByRunName(string runName, object[] dataValue)
{
return PlcWriteByRunName(runName, 0, dataValue);
}
public bool PlcWriteByEquipKey(string equipKey, int shifting, object[] dataValue)
{
return PlcWrite(equipKey, string.Empty, shifting, dataValue);
}
public bool PlcWriteByEquipKey(string equipKey, object[] dataValue)
{
return PlcWriteByEquipKey(equipKey, 0, dataValue);
}
public bool PlcWriteByDataKey(DataKeyValue dataKey, int shifting, object[] dataValue)
{
return PlcWriteByEquipKey(dataKey.EquipKey, shifting, dataValue);
}
public bool PlcWriteByDataKey(DataKeyValue dataKey, object[] dataValue)
{
return PlcWriteByDataKey(dataKey, 0, dataValue);
}
public bool PlcWriteByDataKey(DataKeyValue dataKey, string dataValue)
{
object[] buff = null;
buff = new object[dataKey.EquipData.Len];
for (int i = 0; i < buff.Length; i++)
{
buff[i] = 0;
}
object[] planIDData = Mesnac.Basic.DataProcessor.ToPLCDataArray(dataValue);
if (planIDData.Length <= buff.Length)
{
Array.Copy(planIDData, buff, planIDData.Length);
}
else
{
Array.Copy(planIDData, buff, buff.Length);
}
return PlcWriteByDataKey(dataKey, buff);
}
//增加是否输出日志
public bool PlcWriteByEquipKey(string equipKey, int shifting, object[] dataValue, bool isOutLog)
{
return PlcWrite(equipKey, string.Empty, shifting, dataValue, isOutLog);
}
//增加是否输出日志
public bool PlcWriteByDataKey(DataKeyValue dataKey, int shifting, object[] dataValue, bool isOutLog)
{
return PlcWriteByEquipKey(dataKey.EquipKey, shifting, dataValue, isOutLog);
}
//增加是否输出日志
public bool PlcWriteByDataKey(DataKeyValue dataKey, object[] dataValue, bool isOutLog)
{
return PlcWriteByDataKey(dataKey, 0, dataValue, isOutLog);
}
/// <summary>
/// 向Plc变量写入float浮点数下传Plc
/// </summary>
/// <param name="dataKey"></param>
/// <param name="dataValue"></param>
/// <returns></returns>
public bool PlcWriteFloatByDataKey(DataKeyValue dataKey, float dataValue)
{
string equipName = dataKey.EquipKey;
if (dataKey.EquipKey.Contains("."))
{
equipName = dataKey.EquipKey.Split(new char[] { '.' })[0];
}
if (Factory.Instance.AllEquips[equipName].Main.Brand.Equals("Siemens", StringComparison.CurrentCultureIgnoreCase))
{
return PlcWriteByDataKey(dataKey, 0, Mesnac.Basic.DataProcessor.ToSiemensPLCDataArray(dataValue));
}
else
{
return PlcWriteByDataKey(dataKey, 0, Mesnac.Basic.DataProcessor.ToPLCDataArray(dataValue));
}
}
/// <summary>
/// 向Plc变量写入float浮点数下传Plc
/// </summary>
/// <param name="dataKey"></param>
/// <param name="dataValue"></param>
/// <param name="isOutLog"></param>
/// <returns></returns>
public bool PlcWriteFloatByDataKey(DataKeyValue dataKey, float dataValue, bool isOutLog)
{
string equipName = dataKey.EquipKey;
if (dataKey.EquipKey.Contains("."))
{
equipName = dataKey.EquipKey.Split(new char[] { '.' })[0];
}
if (Factory.Instance.AllEquips[equipName].Main.Brand.Equals("Siemens", StringComparison.CurrentCultureIgnoreCase))
{
return PlcWriteByDataKey(dataKey, 0, Mesnac.Basic.DataProcessor.ToSiemensPLCDataArray(dataValue), isOutLog);
}
else
{
return PlcWriteByDataKey(dataKey, 0, Mesnac.Basic.DataProcessor.ToPLCDataArray(dataValue), isOutLog);
}
}
#endregion
#region PptPlcData表写入操作
/// <summary>
/// 把设备变量的值写入PptPlcData表
/// </summary>
/// <param name="dataKey">设备变量</param>
/// <param name="equipKey">设备</param>
/// <param name="shifting">偏移</param>
/// <param name="dataValue">值数组</param>
/// <returns></returns>
public bool DataWrite(string dataKey, string equipKey, int shifting, object[] dataValue)
{
if (string.IsNullOrWhiteSpace(dataKey))
{
dataKey = equipKey;
}
if (string.IsNullOrWhiteSpace(equipKey))
{
equipKey = dataKey;
}
DbHelper dbHelper = Mesnac.Basic.DataSourceFactory.Instance.GetDbHelper(Mesnac.Basic.DataSourceFactory.MCDbType.Local);
if (dbHelper == null)
{
throw new Exception(Mesnac.Basic.LanguageHelper.DataBaseConnectError);
}
dbHelper.CommandType = System.Data.CommandType.Text;
dbHelper.ClearParameter();
#region 支持SQL2000
StringBuilder sqlstr = new StringBuilder("INSERT INTO PptPlcData (PlcSchemaField, EquipRunName, PlcDataValue, PlcDataIndex, PlcDownState) ");
for (int i = 0; i < dataValue.Length; i++)
{
object obj = dataValue[i];
if (obj == null || obj == DBNull.Value)
{
obj = string.Empty;
}
string key1 = "@PlcSchemaField" + i.ToString();
string key2 = "@EquipRunName" + i.ToString();
string key3 = "@PlcDataValue" + i.ToString();
string key4 = "@PlcDataIndex" + i.ToString();
sqlstr.Append(" (select ").Append(key1).Append(" as PlcSchemaField").Append(",").Append(key2).Append(" as EquipRunName").Append(",").Append(key3).Append(" as PlcDataValue").Append(",").Append(key4).Append(" as PlcDataIndex").Append(",0 as PlcDownState)");
if (i < dataValue.Length - 1)
{
sqlstr.AppendLine("union all");
}
if (obj is PlcDataInfo)
{
PlcDataInfo data = obj as PlcDataInfo;
dbHelper.AddParameter(key1, string.IsNullOrWhiteSpace(data.PlcSchemaField) ? dataKey : data.PlcSchemaField);
dbHelper.AddParameter(key2, string.IsNullOrWhiteSpace(data.EquipRunName) ? equipKey : data.EquipRunName);
dbHelper.AddParameter(key3, data.PlcDataValue == null ? 0 : data.PlcDataValue);
dbHelper.AddParameter(key4, (shifting + i).ToString());
}
else
{
dbHelper.AddParameter(key1, dataKey);
dbHelper.AddParameter(key2, equipKey);
dbHelper.AddParameter(key3, obj);
dbHelper.AddParameter(key4, (shifting + i).ToString());
}
} //插入语句
#endregion
dbHelper.CommandText = sqlstr.ToString();
dbHelper.ExecuteNonQuery();
return true;
}
public bool DataWrite(string dataKey, string equipKey, object[] dataValue)
{
return DataWrite(dataKey, equipKey, 0, dataValue);
}
public bool DataWrite(string equipKey, object[] dataValue)
{
return DataWrite(equipKey, equipKey, 0, dataValue);
}
public bool DataWrite(DataKeyValue dataKey, int shifting, object[] dataValue)
{
return DataWrite(dataKey.Name, dataKey.EquipRunName, shifting, dataValue);
}
public bool DataWrite(DataKeyValue dataKey, object[] dataValue)
{
return DataWrite(dataKey, 0, dataValue);
}
#endregion
#endregion
#region 属性定义
#region 自定义设备变量
/// <summary>
/// 最小计划数由PLC实时读取
/// </summary>
public int MinPlanNum = 3;
#region PC在线标志
/// <summary>
/// 开门料仓号
/// </summary>
public DataKeyValue ChemicalWeighing_PC_Online = new DataKeyValue("PC_Online");
#endregion
/// <summary>
/// 小料PLC在线标志
/// </summary>
public DataKeyValue ChemicalWeighing_PLC_Online_Flag = new DataKeyValue("PLC_Online_Flag");
/// <summary>
/// 等待计划数
/// </summary>
public DataKeyValue ChemicalWeighing_Scheduled_Num = new DataKeyValue("Scheduled_Num");
#region 自动下传计划相关变量
/// <summary>
/// 小料PLC请求计划交互信息
/// </summary>
public DataKeyValue ChemicalWeighing_PLC_LoadingStatus = new DataKeyValue("PLC_LoadingStatus");
/// <summary>
/// 小料PC计划反馈交互信息
/// </summary>
public DataKeyValue ChemicalWeighing_PC_LoadingStatus = new DataKeyValue("PC_LoadingStatus");
/// <summary>
/// 速度1
/// </summary>
public DataKeyValue DwSpeed = new DataKeyValue("DwSpeed");
#endregion
#region 自动更新计划状态相关变量
/// <summary>
/// 小料PLC计划状态变化交互PLC请求信息
/// </summary>
public DataKeyValue ChemicalWeighing_PLC_Plan_Status_ShakeHand = new DataKeyValue("PLC_Plan_Status_ShakeHand");
/// <summary>
/// PC计划状态根据PLC状态更新交互信息
/// </summary>
public DataKeyValue ChemicalWeighing_PLC_Plan_Status_FeedBack = new DataKeyValue("PLC_Plan_Status_FeedBack");
/// <summary>
/// 小料计划序号
/// </summary>
public DataKeyValue ChemicalWeighing_Plan_Serial = new DataKeyValue("Plan_Serial");
/// <summary>
/// 小料计划状态
/// </summary>
public DataKeyValue ChemicalWeighing_Plan_Status = new DataKeyValue("Plan_Status");
/// <summary>
/// 小料计划完成数
/// </summary>
public DataKeyValue ChemicalWeighing_Plan_Number = new DataKeyValue("Plan_Number");
/// <summary>
/// 小料计划剩余数量
/// </summary>
public DataKeyValue ChemicalWeighing_Remain_Number = new DataKeyValue("Remain_Number");
#endregion
#region HMI配方列表请求相关变量
/// <summary>
/// 小料HMI配方查询请求信息
/// </summary>
public DataKeyValue ChemicalWeighing_HMI_Request_Recipe_Name_ShakeHand = new DataKeyValue("HMI_Request_Recipe_Name_ShakeHand");
/// <summary>
/// PCHMI配方查询请求信息响应
/// </summary>
public DataKeyValue ChemicalWeighing_HMI_Request_Recipe_Name_FeedBack = new DataKeyValue("HMI_Request_Recipe_Name_FeedBack");
/// <summary>
/// 读取到的机台号
/// </summary>
public DataKeyValue ChemicalWeighing_Sys_Machine = new DataKeyValue("Sys_Machine");
/// <summary>
/// 读取到的配方名称
/// </summary>
public DataKeyValue ChemicalWeighing_Plan_Code = new DataKeyValue("Plan_Code");
#endregion
#region HMI根据配方请求添加计划相关变量
/// <summary>
/// 小料HMI配方添加计划请求信息
/// </summary>
public DataKeyValue ChemicalWeighing_HMI_Confirm_Recipe_ShakeHand = new DataKeyValue("HMI_Confirm_Recipe_ShakeHand");
/// <summary>
/// PCHMI配方添加计划请求信息响应
/// </summary>
public DataKeyValue ChemicalWeighing_HMI_Confirm_Recipe_FeedBack = new DataKeyValue("HMI_Confirm_Recipe_FeedBack");
/// <summary>
/// 读取到的机台号
/// </summary>
public DataKeyValue ChemicalWeighing_Sys_Machine1 = new DataKeyValue("Sys_Machine1");
/// <summary>
/// 读取到的配方名称
/// </summary>
public DataKeyValue ChemicalWeighing_Plan_Code1 = new DataKeyValue("Plan_Code1");
/// <summary>
/// 设定数量
/// </summary>
public DataKeyValue ChemicalWeighing_HMI_Plan_Num = new DataKeyValue("HMI_Plan_Num");
#endregion
#region HMI请求修改计划相关变量
/// <summary>
/// PLCHMI修改计划请求信息
/// </summary>
public DataKeyValue ChemicalWeighing_HMI_Request_Recipe_Change_ShakeHand = new DataKeyValue("HMI_Request_Recipe_Change_ShakeHand");
/// <summary>
/// PCHMI修改计划请求信息响应
/// </summary>
public DataKeyValue ChemicalWeighing_HMI_Request_Recipe_Change_FeedBack = new DataKeyValue("HMI_Request_Recipe_Change_FeedBack");
/// <summary>
/// 命令0默认 1刷新 2上移 3下移 4修改车数 5删除计划
/// </summary>
public DataKeyValue ChemicalWeighing_HMI_Request_Recipe_Change_Command = new DataKeyValue("HMI_Request_Recipe_Change_Command");
/// <summary>
/// 读取到的机台号
/// </summary>
public DataKeyValue ChemicalWeighing_Sys_Machine2 = new DataKeyValue("Sys_Machine2");
/// <summary>
/// 读取到的计划号
/// </summary>
public DataKeyValue ChemicalWeighing_HMIChange_PlanId = new DataKeyValue("HMIChange_PlanId");
/// <summary>
/// 设定数量
/// </summary>
public DataKeyValue ChemicalWeighing_HMIChange_PlanNum = new DataKeyValue("HMIChange_PlanNum");
#endregion
#region 自动存盘相关变量
/// <summary>
/// PLC存盘请求
/// </summary>
public DataKeyValue ChemicalWeighing_PLC_Request_Save_ShakeHand = new DataKeyValue("Plc_Request_Save_ShakeHand");
/// <summary>
/// PC存盘反馈信息
/// </summary>
public DataKeyValue ChemicalWeighing_PC_Request_Save_FeedBack = new DataKeyValue("PC_Request_Save_FeedBack");
/// <summary>
/// 报表基本信息
/// </summary>
public DataKeyValue ChemicalWeighing_Report_Update_Block_BaseInf = new DataKeyValue("Report_Update_Block_BaseInf");
/// <summary>
/// 物料报表信息
/// </summary>
public DataKeyValue ChemicalWeighing_Report_Update_Block_Material_Report = new DataKeyValue("Report_Update_Block_Material_Report");
#endregion
#region 上位机修改计划数、终止计划相关变量
/// <summary>
/// PC下传终止计划状态
/// </summary>
public DataKeyValue ChemicalWeighing_Plan_Status_Com_ShakeHand = new DataKeyValue("Plan_Status_Com_ShakeHand");
/// <summary>
/// PLC终止计划状态反馈
/// </summary>
public DataKeyValue ChemicalWeighing_Plan_Status_Com_FeedBack = new DataKeyValue("Plan_Status_Com_FeedBack");
#endregion
#region 条码扫描后下传到PLC的命令相关变量
/// <summary>
/// 开门料仓号
/// </summary>
public DataKeyValue ChemicalWeighing_Hopper_No_103 = new DataKeyValue("Hopper_No_103");
/// <summary>
/// 条码开门命令
/// </summary>
public DataKeyValue ChemicalWeighing_ScanCommand = new DataKeyValue("Command");
/// <summary>
/// 条码开门握手信号
/// </summary>
public DataKeyValue ChemicalWeighing_Open_door_Command_ShakeHand = new DataKeyValue("Open_door_Command_ShakeHand");
#endregion
#endregion
#region 自动写入物料名称相关变量
/// <summary>
/// PLC物料名称下传请求
/// </summary>
public DataKeyValue ChemicalWeighing_PLC_LoadingConfig = new DataKeyValue("PLC_LoadingConfig");
/// <summary>
/// PC物料名称下传反馈
/// </summary>
public DataKeyValue ChemicalWeighing_PC_LoadingConfig = new DataKeyValue("PC_LoadingConfig");
#endregion
#endregion
#region 冠合上位机计划下传
//下位机准备信号(上位机下传时读取)
public DataKeyValue ChemicalWeighing_PC_ConfirmRemote = new DataKeyValue("ConfirmRemote");
//下位机准备信号(上位机下传时读取)
public DataKeyValue ChemicalWeighing_PC_ConfirmReady = new DataKeyValue("ConfirmReady");
//配方编号、名称
public DataKeyValue ChemicalWeighing_PC_RecipeCode = new DataKeyValue("Recipe_Code");
public DataKeyValue ChemicalWeighing_PC_RecipeName = new DataKeyValue("recipe_name");
//设定车数、格数、层数
public DataKeyValue ChemicalWeighing_PC_SetCarNumber = new DataKeyValue("set_carnumber");
public DataKeyValue ChemicalWeighing_PC_SetGeNumber = new DataKeyValue("set_genumber");
public DataKeyValue ChemicalWeighing_PC_SetLineNumber = new DataKeyValue("set_linenumber");
//混料速度
public DataKeyValue ChemicalWeighing_PC_Hlsd1 = new DataKeyValue("hlsd1");
public DataKeyValue ChemicalWeighing_PC_Hlsd2 = new DataKeyValue("hlsd2");
public DataKeyValue ChemicalWeighing_PC_Hlsd3 = new DataKeyValue("hlsd3");
//进料时间、混料时间
public DataKeyValue ChemicalWeighing_PC_Jlsj = new DataKeyValue("jl_sj");
public DataKeyValue ChemicalWeighing_PC_Hlsj = new DataKeyValue("hl_sj");
//VCC、GFA、树脂进料、进料误差
public DataKeyValue ChemicalWeighing_PC_VCCJl = new DataKeyValue("vcc_jl");
public DataKeyValue ChemicalWeighing_PC_VCCJlWc = new DataKeyValue("vcc_jlwc");
public DataKeyValue ChemicalWeighing_PC_GFAJl = new DataKeyValue("gfa_jl");
public DataKeyValue ChemicalWeighing_PC_GFAJlWc = new DataKeyValue("gfa_jlwc");
public DataKeyValue ChemicalWeighing_PC_SZJl = new DataKeyValue("sz_jl");
public DataKeyValue ChemicalWeighing_PC_SZJlWc = new DataKeyValue("sz_jlwc");
#endregion
}
}