using Mesnac.Action.ChemicalWeighing.Entity; using System; using System.Collections.Generic; using System.ComponentModel; using System.Data; using System.Drawing; using System.Linq; using System.Text; using System.Threading.Tasks; using System.Windows.Forms; namespace Mesnac.Action.ChemicalWeighing.EngineeringDebuggingMode.InstrumentDataStateMonitor { public partial class InstrumentDataStateMonitor : Form { string DmName_3005 = "PR1DBT01"; string DmName_3006 = "SPV1DBT01"; public InstrumentDataStateMonitor() { InitializeComponent(); StateMonitor_3005(DmName_3005); StateMonitor_3006(DmName_3006); } private void DmChange_3005_SelectedIndexChanged(object sender, EventArgs e) { DmName_3005 = dmNameValue[DmChange_3005.Text]; StateMonitor_3005(DmName_3005); } private void DmChange_3006_SelectedIndexChanged(object sender, EventArgs e) { DmName_3006 = dmNameValue[DmChange_3006.Text]; StateMonitor_3006(DmName_3006); } private void Refresh_Click(object sender, EventArgs e) { StateMonitor_3005(DmName_3005); StateMonitor_3006(DmName_3006); } private void StateMonitor_3005(string dmName) { Min_3005.Text = PlcCommunicationUtil.GetDataToString(dmName, "_Min"); Max_3005.Text = PlcCommunicationUtil.GetDataToString(dmName, "_Max"); Value_3005.Text = PlcCommunicationUtil.GetDataToString(dmName, "_Value"); Alarm_3005.Text = PlcCommunicationUtil.GetDataToString(dmName, "_Alarm"); } private void StateMonitor_3006(string dmName) { Mlin_3006.Text = PlcCommunicationUtil.GetDataToString(dmName, "_Mlin"); Max_3006.Text = PlcCommunicationUtil.GetDataToString(dmName, "_Max"); SetValue_3006.Text = PlcCommunicationUtil.GetDataToString(dmName, "_SetValue"); Alarm_3006.Text = PlcCommunicationUtil.GetDataToString(dmName, "_Alarm"); } private IDictionary dmNameValue = new Dictionary() { ["输送线A_主气源压力传感器"] = "PR1DBT01", ["输送线A_1号压送罐压力传感器"] = "PR1DBT02", ["输送线A_2号压送罐压力传感器"] = "PR1DBT03", ["输送线A_出料口检测压力传感器"] = "PR1DBT04", ["输送线B_主气源压力传感器"] = "PR2DBT01", ["输送线B_1号压送罐压力传感器"] = "PR2DBT02", ["输送线B_2号压送罐压力传感器"] = "PR2DBT03", ["输送线B_出料口检测压力传感器"] = "PR2DBT04", ["输送线C_主气源压力传感器"] = "PR3DBT01", ["输送线C_1号压送罐压力传感器"] = "PR3DBT02", ["输送线C_2号压送罐压力传感器"] = "PR3DBT03", ["输送线C_出料口检测压力传感器"] = "PR3DBT04", ["大仓A压力传感器"] = "PR1ASI01", ["大仓B压力传感器"] = "PR1BSI01", ["大仓C压力传感器"] = "PR1CSI01", ["大仓D压力传感器"] = "PR1DSI01", ["大仓E压力传感器"] = "PR1ESI01", ["大仓F压力传感器"] = "PR1FSI01", ["大仓G压力传感器"] = "PR1GSI01", ["大仓H压力传感器"] = "PR1HSI01", ["大仓I压力传感器"] = "PR1ISI01", ["大仓J压力传感器"] = "PR1JSI01", ["大仓O压力传感器"] = "PR1OSI01", ["输送线A_管道压力传感器"] = "PR1PCP01", ["输送线B_管道压力传感器"] = "PR1PCP02", ["输送线C_管道压力传感器"] = "PR1PCP03", ["大仓A连续料位计"] = "LS1ASI01", ["大仓B连续料位计"] = "LS1BSI01", ["大仓C连续料位计"] = "LS1CSI01", ["大仓D连续料位计"] = "LS1DSI01", ["大仓E连续料位计"] = "LS1ESI01", ["大仓F连续料位计"] = "LS1FSI01", ["大仓G连续料位计"] = "LS1GSI01", ["大仓H连续料位计"] = "LS1HSI01", ["大仓I连续料位计"] = "LS1ISI01", ["大仓J连续料位计"] = "LS1JSI01", ["大仓O连续料位计"] = "LS1OSI01", ["大仓A顶部热电阻/测温开关"] = "HR1ASI01", ["大仓B顶部热电阻/测温开关"] = "HR1BSI01", ["大仓C顶部热电阻/测温开关"] = "HR1CSI01", ["大仓D顶部热电阻/测温开关"] = "HR1DSI01", ["大仓E顶部热电阻/测温开关"] = "HR1ESI01", ["大仓F顶部热电阻/测温开关"] = "HR1FSI01", ["大仓G顶部热电阻/测温开关"] = "HR1GSI01", ["大仓H顶部热电阻/测温开关"] = "HR1HSI01", ["大仓I顶部热电阻/测温开关"] = "HR1ISI01", ["大仓J顶部热电阻/测温开关"] = "HR1JSI01", ["大仓O顶部热电阻/测温开关"] = "HR1OSI01", ["输送线A_主管电磁比例阀"] = "SPV1DBT01", ["输送线A_辅管电磁比例阀"] = "SPV1DBT02", ["输送线B_主管电磁比例阀"] = "SPV2DBT01", ["输送线B_辅管电磁比例阀"] = "SPV2DBT02", ["输送线C_主管电磁比例阀"] = "SPV3DBT01", ["输送线C_辅管电磁比例阀"] = "SPV3DBT02", ["大仓A低部热电阻/测温开关"] = "From_SiloA", ["大仓B低部热电阻/测温开关"] = "From_SiloB", ["大仓C低部热电阻/测温开关"] = "From_SiloC", ["大仓D低部热电阻/测温开关"] = "From_SiloD", ["大仓E低部热电阻/测温开关"] = "From_SiloE", ["大仓F低部热电阻/测温开关"] = "From_SiloF", ["大仓G低部热电阻/测温开关"] = "From_SiloG", ["大仓H低部热电阻/测温开关"] = "From_SiloH", ["大仓I低部热电阻/测温开关"] = "From_SiloI", ["大仓J低部热电阻/测温开关"] = "From_SiloJ", ["大仓K低部热电阻/测温开关"] = "From_SiloK", ["大仓L低部热电阻/测温开关"] = "From_SiloL", ["大仓M低部热电阻/测温开关"] = "From_SiloM", ["大仓N低部热电阻/测温开关"] = "From_SiloN", ["大仓O低部热电阻/测温开关"] = "From_SiloO" }; } }