ReportReadDb 读取报表的问题

dep
我叫锄头 12 months ago
parent 09e043b212
commit 64bcf76309

@ -28,6 +28,7 @@ using Mesnac.Action.ChemicalWeighing.InterfaceDocking;
using Mesnac.Action.ChemicalWeighing.Report; using Mesnac.Action.ChemicalWeighing.Report;
using Mesnac.Action.ChemicalWeighing.InterfaceDocking.DockingEntity; using Mesnac.Action.ChemicalWeighing.InterfaceDocking.DockingEntity;
using Mesnac.Core.Service; using Mesnac.Core.Service;
using Mesnac.Basic;
namespace Mesnac.Action.ChemicalWeighing.MainDetailControl namespace Mesnac.Action.ChemicalWeighing.MainDetailControl
{ {
@ -299,7 +300,12 @@ namespace Mesnac.Action.ChemicalWeighing.MainDetailControl
if (ReadFlag >= 30) if (ReadFlag >= 30)
{ {
ReadFlag = 0; ReadFlag = 0;
var readName = UserInfo.Instance.RealName;
if (!string.IsNullOrEmpty(readName) && readName!= "mesnac" && readName != "Edit")
{
ReportReadDb.ReadFeededDry(); ReportReadDb.ReadFeededDry();
}
} }

@ -61,12 +61,13 @@ namespace Mesnac.Action.ChemicalWeighing.Report
} }
//水 ///热水秤A
if (nornalStatus.RdyRpt_W1) if (nornalStatus.RdyRpt_W1)
{ {
FeededWaterHA(dB2111Helper.hwReport_A); FeededWaterHA(dB2111Helper.hwReport_A);
} }
///冷水秤A
if (nornalStatus.RdyRpt_W2) if (nornalStatus.RdyRpt_W2)
{ {
FeededWaterCA(dB2111Helper.cwReport_A); FeededWaterCA(dB2111Helper.cwReport_A);
@ -77,6 +78,7 @@ namespace Mesnac.Action.ChemicalWeighing.Report
{ {
FeededWaterHB(dB2111Helper.hwReport_B); FeededWaterHB(dB2111Helper.hwReport_B);
} }
///冷水秤B
if (nornalStatus.RdyRpt_W4) if (nornalStatus.RdyRpt_W4)
{ {
FeededWaterCB(dB2111Helper.cwReport_B); FeededWaterCB(dB2111Helper.cwReport_B);
@ -123,6 +125,11 @@ namespace Mesnac.Action.ChemicalWeighing.Report
DB2107WriteHelper.CleanWater(4); DB2107WriteHelper.CleanWater(4);
} }
/// <summary>
/// 解决算法有问题
/// </summary>
/// <param name="deviceno"></param>
/// <param name="entity"></param>
private static void FeededDry(int deviceno, ReportDosEntity entity) private static void FeededDry(int deviceno, ReportDosEntity entity)
{ {
@ -130,7 +137,7 @@ namespace Mesnac.Action.ChemicalWeighing.Report
int no = deviceno * 2; int no = deviceno * 2;
if (entity.eqNo == 1) if (entity.eqNo == 1)
{ {
no = deviceno-1; no = no - 1;
} }
var actValue = Convert.ToInt32(entity.actValue); var actValue = Convert.ToInt32(entity.actValue);
string logName = $"螺旋{deviceno}向湿混机 [{no}] 投料 {actValue}"; string logName = $"螺旋{deviceno}向湿混机 [{no}] 投料 {actValue}";

@ -70,7 +70,7 @@ namespace Mesnac.Action.ChemicalWeighing.Test
mCButton.Click += MCButton_Click; mCButton.Click += MCButton_Click;
System.Timers.Timer t = new System.Timers.Timer(1000*20);//实例化Timer类设置间隔时间为10000毫秒 System.Timers.Timer t = new System.Timers.Timer(1000);//实例化Timer类设置间隔时间为10000毫秒
t.Elapsed += new System.Timers.ElapsedEventHandler(theout);//到达时间的时候执行事件; t.Elapsed += new System.Timers.ElapsedEventHandler(theout);//到达时间的时候执行事件;
t.AutoReset = true;//设置是执行一次false还是一直执行(true) t.AutoReset = true;//设置是执行一次false还是一直执行(true)
t.Enabled = true;//是否执行System.Timers.Timer.Elapsed事件 t.Enabled = true;//是否执行System.Timers.Timer.Elapsed事件

@ -21,7 +21,6 @@ namespace DataBlockHelper
SiemensPLCS siemensPLCS = SiemensPLCS.S1500; SiemensPLCS siemensPLCS = SiemensPLCS.S1500;
SiemensS7Net s7 = new SiemensS7Net(siemensPLCS); SiemensS7Net s7 = new SiemensS7Net(siemensPLCS);
s7.SetPersistentConnection(); s7.SetPersistentConnection();
s7.IpAddress = "172.18.4.100"; s7.IpAddress = "172.18.4.100";
s7.Port = 102; s7.Port = 102;
var su = s7.ConnectServer(); var su = s7.ConnectServer();

Loading…
Cancel
Save