You cannot select more than 25 topics Topics must start with a letter or number, can include dashes ('-') and can be up to 35 characters long.
lj_plc/Actions/ChemicalWeighing/Mesnac.Action.ChemicalWeighing/ManualControl/InitAction.cs

348 lines
9.5 KiB
C#

using DataBlockHelper;
using HslCommunication;
using Mesnac.Action.Base;
using Mesnac.Controls.Base;
using System;
using System.Collections.Generic;
using System.Linq;
using System.Text;
using System.Windows.Forms;
namespace Mesnac.Action.ChemicalWeighing.ManualControl
{
public class InitAction : ChemicalWeighingAction, IAction
{
List<DbMCControl> McControllist;
OperateResult<byte[]> Read;
byte[] content;
1 year ago
System.Timers.Timer timer;
bool State1;
bool State2;
byte Byt;
public void Run(RuntimeParameter runtime)
{
base.RunIni(runtime); //必须要调用的
1 year ago
//ReadFromPlc();
InitTimer();
timer.Start();
}
private void ReadFromPlc(Object sender, System.Timers.ElapsedEventArgs e)
{
McControllist = GetAllDbMCControlsByOption(DbOptionTypes.InitData);//获取所有待初始化控件
1 year ago
IBaseControl WaterActualValue1 = GetBaseControl("WaterActualValue1");
IBaseControl WaterActualValue2 = GetBaseControl("WaterActualValue2");
IBaseControl WaterActualValue3 = GetBaseControl("WaterActualValue3");
IBaseControl WaterActualValue4 = GetBaseControl("WaterActualValue4");
1 year ago
IBaseControl WaterMetValue1 = GetBaseControl("WaterMetValue1");
IBaseControl WaterMetValue2 = GetBaseControl("WaterMetValue2");
IBaseControl WaterMetValue3 = GetBaseControl("WaterMetValue3");
IBaseControl WaterMetValue4 = GetBaseControl("WaterMetValue4");
IBaseControl SpiralActValue1 = GetBaseControl("SpiralActValue1");
IBaseControl SpiralActValue2 = GetBaseControl("SpiralActValue2");
IBaseControl SpiralActValue3 = GetBaseControl("SpiralActValue3");
IBaseControl SpiralActValue4 = GetBaseControl("SpiralActValue4");
1 year ago
IBaseControl MetageState1 = GetBaseControl("MetageState1");
IBaseControl MetageState2 = GetBaseControl("MetageState2");
IBaseControl MetageState3 = GetBaseControl("MetageState3");
IBaseControl MetageState4 = GetBaseControl("MetageState4");
IBaseControl WaterOutState1 = GetBaseControl("WaterOutState1");
IBaseControl WaterOutState2 = GetBaseControl("WaterOutState2");
IBaseControl WaterOutState3 = GetBaseControl("WaterOutState3");
IBaseControl WaterOutState4 = GetBaseControl("WaterOutState4");
IBaseControl SpiralState1 = GetBaseControl("SpiralState1");
IBaseControl SpiralState2 = GetBaseControl("SpiralState2");
IBaseControl SpiralState3 = GetBaseControl("SpiralState3");
IBaseControl SpiralState4 = GetBaseControl("SpiralState4");
Read = PlcConnect.Instance.Read("DB2119.22.0", 2);
content = Read.Content;
WaterActualValue1.MCValue = PlcConnect.Instance.ByteTransform.TransInt16(content, 0);
Read = PlcConnect.Instance.Read("DB2119.2.0", 2);
content = Read.Content;
WaterActualValue2.MCValue = PlcConnect.Instance.ByteTransform.TransInt16(content, 0);
Read = PlcConnect.Instance.Read("DB2119.32.0", 2);
content = Read.Content;
WaterActualValue3.MCValue = PlcConnect.Instance.ByteTransform.TransInt16(content, 0);
Read = PlcConnect.Instance.Read("DB2119.12.0", 2);
content = Read.Content;
WaterActualValue4.MCValue = PlcConnect.Instance.ByteTransform.TransInt16(content, 0);
1 year ago
Read = PlcConnect.Instance.Read("DB2119.24.0", 2);
content = Read.Content;
WaterMetValue1.MCValue = PlcConnect.Instance.ByteTransform.TransInt16(content, 0);
Read = PlcConnect.Instance.Read("DB2119.4.0", 2);
content = Read.Content;
WaterMetValue2.MCValue = PlcConnect.Instance.ByteTransform.TransInt16(content, 0);
Read = PlcConnect.Instance.Read("DB2119.34.0", 2);
content = Read.Content;
WaterMetValue3.MCValue = PlcConnect.Instance.ByteTransform.TransInt16(content, 0);
Read = PlcConnect.Instance.Read("DB2119.14.0", 2);
content = Read.Content;
WaterMetValue4.MCValue = PlcConnect.Instance.ByteTransform.TransInt16(content, 0);
Read = PlcConnect.Instance.Read("DB2119.42.0", 2);
content = Read.Content;
SpiralActValue1.MCValue = PlcConnect.Instance.ByteTransform.TransInt16(content, 0);
Read = PlcConnect.Instance.Read("DB2119.64.0", 2);
content = Read.Content;
SpiralActValue2.MCValue = PlcConnect.Instance.ByteTransform.TransInt16(content, 0);
Read = PlcConnect.Instance.Read("DB2119.86.0", 2);
content = Read.Content;
SpiralActValue3.MCValue = PlcConnect.Instance.ByteTransform.TransInt16(content, 0);
1 year ago
Read = PlcConnect.Instance.Read("DB2119.28.0", 1);
content = Read.Content;
Byt = content[0];
State1 = Byt.GetBit(2);
State2 = Byt.GetBit(6);
if (State1)
{
MetageState1.MCValue = "正在称量";
}
else
{
MetageState1.MCValue = "停止称量";
}
if (State2)
{
WaterOutState1.MCValue = "正在排水";
}
else
{
WaterOutState1.MCValue = "停止排水";
}
Read = PlcConnect.Instance.Read("DB2119.8.0", 1);
content = Read.Content;
Byt = content[0];
State1 = Byt.GetBit(2);
State2 = Byt.GetBit(6);
if (State1)
{
MetageState2.MCValue = "正在称量";
}
else
{
MetageState2.MCValue = "停止称量";
}
if (State2)
{
WaterOutState2.MCValue = "正在排水";
}
else
{
WaterOutState2.MCValue = "停止排水";
}
Read = PlcConnect.Instance.Read("DB2119.38.0", 1);
content = Read.Content;
Byt = content[0];
State1 = Byt.GetBit(2);
State2 = Byt.GetBit(6);
if (State1)
{
MetageState3.MCValue = "正在称量";
}
else
{
MetageState3.MCValue = "停止称量";
}
if (State2)
{
WaterOutState3.MCValue = "正在排水";
}
else
{
WaterOutState3.MCValue = "停止排水";
}
Read = PlcConnect.Instance.Read("DB2119.18.0", 1);
content = Read.Content;
Byt = content[0];
State1 = Byt.GetBit(2);
State2 = Byt.GetBit(6);
if (State1)
{
MetageState4.MCValue = "正在称量";
}
else
{
MetageState4.MCValue = "停止称量";
}
if (State2)
{
WaterOutState4.MCValue = "正在排水";
}
else
{
WaterOutState4.MCValue = "停止排水";
}
Read = PlcConnect.Instance.Read("DB2119.60.0", 1);
content = Read.Content;
Byt = content[0];
State1 = Byt.GetBit(2);
if (State1)
{
SpiralState1.MCValue = "正在螺旋";
}
else
{
SpiralState1.MCValue = "停止螺旋";
}
Read = PlcConnect.Instance.Read("DB2119.82.0", 1);
content = Read.Content;
Byt = content[0];
State1 = Byt.GetBit(2);
if (State1)
{
SpiralState2.MCValue = "正在螺旋";
}
else
{
SpiralState2.MCValue = "停止螺旋";
}
Read = PlcConnect.Instance.Read("DB2119.104.0", 1);
content = Read.Content;
Byt = content[0];
State1 = Byt.GetBit(2);
if (State1)
{
SpiralState3.MCValue = "正在螺旋";
}
else
{
SpiralState3.MCValue = "停止螺旋";
}
//Read = PlcConnect.Instance.Read("DB2119..0", 1);
//content = Read.Content;
//Byt = content[0];
//State1 = Byt.GetBit(2);
//if (State1)
//{
// MetageState4.MCValue = "正在螺旋";
//}
//else
//{
// MetageState4.MCValue = "停止螺旋";
//}
}
private void InitTimer()
{
//设置定时间隔(毫秒为单位)
int interval = 900;
timer = new System.Timers.Timer(interval);
//设置执行一次false还是一直执行(true)
timer.AutoReset = true;
//设置是否执行System.Timers.Timer.Elapsed事件
timer.Enabled = true;
//绑定Elapsed事件
timer.Elapsed += new System.Timers.ElapsedEventHandler(ReadFromPlc);
}
1 year ago
private IBaseControl GetBaseControl(string name)
{
return McControllist.Where(t => t.BaseControl.MCKey != null && t.BaseControl.MCKey == name).FirstOrDefault().BaseControl;
}
1 year ago
}
}